Find the Hypot that’s Right for You
Models | 3805 | 3855 | 3865 | 3870 |
Test Capabilities |
AC Hipot Ground Continuity |
AC Hipot Ground Continuity Insulation Resistance |
AC Hipot DC Hipot Ground Continuity |
AC Hipot DC Hipot Ground Continuity Insulation Resistance |
Test Specifications | AC Hipot Voltage Output = 0-5000VAC Leakage Current Limits = 0.00-20.0mA Output Frequency = 50/60Hz Ground Continuity Current = DC 0.1A ± 0.01A, fixed Resistance Limits = 0.0Ω-1.50Ω |
AC Hipot Voltage Output = 0-5000VAC Leakage Current Limits = 0.00-20.0mA Output Frequency = 50/60Hz Ground Continuity Current = DC 0.1A ± 0.01A, fixed Resistance Limits = 0.0Ω-1.50Ω Insulation Resistance Voltage Output = 30-1000VDC Resistance Range = 1MΩ-50GΩ |
AC Hipot Voltage Output = 0-5000VAC Leakage Current Limits = 0.00-20.0mA Output Frequency = 50/60Hz DC Hipot Voltage Output = 0-6000VDC Leakage Current Limits = 1µA-7.500mA DC Ripple ≤ 5% Ripple RMS at 6KVDC @ 7.5mA, Resistive Load Ground Continuity Current = DC 0.1A ± 0.01A, fixed Resistance Limits = 0.0Ω-1.50Ω |
AC Hipot Voltage Output = 0-5000VAC Leakage Current Limits = 0.00-20.0mA Output Frequency = 50/60Hz DC Hipot Voltage Output = 0-6000VDC Leakage Current Limits = 1µA-7.500mA DC Ripple ≤ 5% Ripple RMS at 6KVDC @ 7.5mA, Resistive Load Ground Continuity Current = DC 0.1A ± 0.01A, fixed Resistance Limits = 0.0Ω-1.50Ω Insulation Resistance Voltage Output = 30-1000VDC Resistance Range = 1MΩ-50GΩ |
Safety | Safety Interlock SmartGFI® Security Access |
Safety Interlock SmartGFI® Security Access |
Safety Interlock SmartGFI® Security Access |
Safety Interlock SmartGFI® Security Access |
Productivity | Programmable Memory Arc Detection Single Step FailCHEK® Cal Alert® |
Programmable Memory Arc Detection Single Step FailCHEK® Cal Alert® |
Programmable Memory Arc Detection Single Step FailCHEK® Cal Alert® |
Programmable Memory Arc Detection Single Step FailCHEK® Cal Alert® |
Automation | USB | USB | USB | USB |
Warranty | Standard 5 Year Warranty | Standard 5 Year Warranty | Standard 5 Year Warranty | Standard 5 Year Warranty |
Production Test Compliance | IEC/UL 60335-1 IEC 60598-1 IEC/UL 60601-1 IEC/UL 60950-1 IEC/UL 61010-1 IEC 61851-1 UL 45A UL 2202 UL 1598/CSA C22.2 No. 250.0-08 |
IEC/UL 60335-1 IEC 60598-1 IEC/UL 60601-1 IEC/UL 60950-1 IEC/UL 61010-1 IEC 61851-1 UL 45A UL 2202 UL 1598/CSA C22.2 No. 250.0-08 |
IEC/UL 60335-1 IEC 60598-1 IEC/UL 60601-1 IEC/UL 60950-1 IEC/UL 61010-1 IEC 61851-1 UL 45A UL 2202 UL 1598/CSA C22.2 No. 250.0-08 |
IEC/UL 60335-1 IEC 60598-1 IEC/UL 60601-1 IEC/UL 60950-1 IEC/UL 61010-1 IEC 61851-1 UL 45A UL 2202 UL 1598/CSA C22.2 No. 250.0-08 |
Type Test Compliance | BS EN 60204-1 IEC/UL 60601-1 IEC 61730-1 UL 1703 UL 2202 UL 1598/CSA C22.2 No. 250.0-08 |
BS EN 60204-1 IEC/UL 60601-1 IEC 61730-1 UL 1703 UL 2202 UL 1598/CSA C22.2 No. 250.0-08 |
BS EN 60204-1 IEC/UL 60601-1 IEC 61730-1 UL 1703 UL 2202 UL 1598/CSA C22.2 No. 250.0-08 |
BS EN 60204-1 IEC/UL 60601-1 IEC 61730-1 UL 1703 UL 2202 UL 1598/CSA C22.2 No. 250.0-08 |
In the Box | Hypot Instrument High Voltage Cable Return Cable Fuse USB Cable Line Cord Adapter Box Interlock Disable Key |
Hypot Instrument High Voltage Cable Return Cable Fuse USB Cable Line Cord Adapter Box Interlock Disable Key |
Hypot Instrument High Voltage Cable Return Cable Fuse USB Cable Line Cord Adapter Box Interlock Disable Key |
Hypot Instrument High Voltage Cable Return Cable Fuse USB Cable Line Cord Adapter Box Interlock Disable Key |
Instrument Dimensions | 8.5 x 3.5 x 11.9 in (215 x 88.1 x 300 mm) | 8.5 x 3.5 x 11.9 in (215 x 88.1 x 300 mm) | 8.5 x 3.5 x 11.9 in (215 x 88.1 x 300 mm) | 8.5 x 3.5 x 11.9 in (215 x 88.1 x 300 mm) |
Weight | 12 lbs (5.46 kg) | 12 lbs (5.46 kg) | 12 lbs (5.46 kg) | 12 lbs (5.46 kg) |
Shipping Dimensions & Weight (out-the-door) | Dimension: 19 x 15 x 10 in Weight: 14 lbs (7 kg) |
Dimension: 19 x 15 x 10 in Weight: 14 lbs (7 kg) |
Dimension: 19 x 15 x 10 in Weight: 14 lbs (7 kg) |
Dimension: 19 x 15 x 10 in Weight: 14 lbs (7 kg) |