New Capability

HypotULTRA® Insulation Resistance Now Reaches 200 GΩ

The industry’s most flexible dielectric analyzer just got more capable. HypotULTRA® 4-in-1 testers now measure insulation resistance up to 200 GΩ – four times the previous ceiling – so you can qualify higher impedance insulation systems on the same platform you already trust for AC/DC hipot, ground continuity, and 40A ground bond testing (on the 7804 and 7854 models only).

View the HypotULTRA Series
HypotULTRA Series Dielectric Analyzer
HypotULTRA® Series · Dielectric Analyzer
200 GΩNew Max IR Range
4×Higher Than Previous 50 GΩ Ceiling
4Models Now Ship With It

What’s New

  • Insulation resistance testing capability increased to 200 GΩ.
  • Built into new HypotULTRA units on models 7800, 7804, 7850, and 7854.
  • Safety Features: Safety interlock, SmartGFI®, and security access.
  • Same ProVOLT®, FailCHEK®, and Charge-LO® workflows operators already know. No new procedures to learn.
  • Provides LabVIEW and IVI instrumentation drivers for creating unit control software.
  • Supports GPIB, ENET, USB, and RS-232 communications interfaces.
  • Ideal for cable, wire harness, aerospace, battery, and high-impedance component manufacturers qualifying insulation systems that require test capabilities above 50 GΩ.

Find the Model That Fits Your Testing Needs

ModelAC
Hipot
DC
Hipot
Ground Bond
(40A)
Ground
Continuity
Insulation
Resistance
200
GΩ IR
EN 50191
7800500 VA*••••
7804•••••••
7820••
7850••••••
7854500 VA*•••••

*Meets 200 mA short circuit requirements. Model 7820 performs AC hipot and ground continuity testing only and does not include insulation resistance (200 GΩ upgrade does not apply).

Insulation Resistance Mode

HypotULTRA® Series · Models 7800, 7804, 7850, and 7854 Only
ParameterRangeResolutionAccuracy
Output Voltage, DC10 – 1,000 VDC1 VDC±(1.5% of setting + 2 V)
1,001 – 6,000 VDC1 VDC±(1.5% of setting + 5 V)
Charging CurrentMaximum > 20 mA peak
HI and LO-Limit, Resistance0.10 MΩ – 99.9 MΩ
(HI-Limit: 0=OFF)
0.01 MΩ±(2% of setting + 2 counts)
100.0 MΩ – 999.9 MΩ0.1 MΩ1,000 – 9,999 ±(5% of setting + 2 counts)
1,000 MΩ – 50,000 MΩ1 MΩ10,000 – 50,000 ±(15% of setting + 2 counts)
50.00 GΩ – 99.99 GΩ0.01 GΩ±(20% of setting + 5 counts)
100.0 GΩ – 200.0 GΩ0.1 GΩ±(30% of setting + 5 counts)
Ramp Up TimerRange: 0.1 – 999.9 sec
Ramp Down TimerRange: 1.0 – 999.9 sec
Dwell TimerRange: 0.5 – 999.9 sec (0=Continuous)
Delay TimerRange: 0.5 – 999.9 sec
Charge-LO0.000 – 3.500 µA or Auto Set

HypotULTRA, FailCHEK, Charge-LO, and SmartGFI are registered trademarks of Associated Research, Inc. ProVOLT is a registered trademark of IKONIX USA LLC.